Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
J Imaging Inform Med ; 37(1): 145-150, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38343236

RESUMO

To assess the effect of digital enhancement on the image quality of radiographs obtained with photostimulable phosphor (PSP) plates partially damaged by ambient light. Radiographs of an aluminum step wedge were obtained using the VistaScan and Express systems. Half of the PSP plates was exposed to ambient light for 0, 10, 30, 60, or 90 s before being scanned. The resulting radiographs were exported with and without digital enhancement. Metrics for brightness, contrast, and contrast-to-noise ratio (CNR) were derived, and the ratio of each metric between the exposed-to-light and non-exposed-to-light halves of the radiographs was calculated. The resulting ratios of the radiographs with digital enhancement were subtracted from those without digital enhancement and compared among each other. For the VistaScan system, digital enhancement partially restored brightness, contrast, and CNR. For the Express system, digital enhancement only restored CNR and not the impact of ambient light on brightness and contrast. Specifically, digital enhancement restored 23.48% of brightness for the VistaScan, while percentages below 1% were observed for the Express. Digital enhancement restored 53.25% of image contrast for the VistaScan and 5.79% for the Express; 40.71% of CNR was restored for the VistaScan, and 35% for the Express. Digital enhancement can partially restore the damage caused by ambient light on the brightness and contrast of PSP-based radiographs obtained with the VistaScan, as well as on CNR for the VistaScan and Express systems. The exposure of PSP plates to light can lead to unnecessary retakes and increased patient exposure to X-rays.

2.
J Imaging Inform Med ; 37(2): 892-898, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38343244

RESUMO

Modern photon counting detectors allow the calculation of virtual monoenergetic or material decomposed X-ray images but are not yet used for dental panoramic radiography systems. To assess the diagnostic potential and image quality of photon counting detectors in dental panoramic radiography, ethics approval from the local ethics committee was obtained for this retrospective study. Conventional CT scans of the head and neck region were segmented into bone and soft tissue. The resulting datasets were used to calculate panoramic equivalent thickness bone and soft tissue images by forward projection, using a geometry like that of conventional panoramic radiographic systems. The panoramic equivalent thickness images were utilized to generate synthetic conventional panoramic radiographs and panoramic virtual monoenergetic radiographs at various energies. The conventional, two virtual monoenergetic images at 40 keV and 60 keV, and material-separated bone and soft tissue panoramic equivalent thickness X-ray images simulated from 17 head CTs were evaluated in a reader study involving three experienced radiologists regarding their diagnostic value and image quality. Compared to conventional panoramic radiographs, the material-separated bone panoramic equivalent thickness image exhibits a higher image quality and diagnostic value in assessing the bone structure p < . 001 and details such as teeth or root canals p < . 001 . Panoramic virtual monoenergetic radiographs do not show a significant advantage over conventional panoramic radiographs. The conducted reader study shows the potential of spectral X-ray imaging for dental panoramic imaging to improve the diagnostic value and image quality.

3.
Clin Oral Investig ; 28(3): 161, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381269

RESUMO

OBJECTIVE: To assess the impact of enhancement filters on the formation of halo artifacts in radiographs of dental implants obtained with a complementary metal oxide semiconductor (CMOS) system. METHODS: Digital radiographs of dental implants placed in dry human mandibles were processed with the Noise Reduction smoothing filter, as well as the Sharpen 1, Sharpen 4, and Sharpen UM high-pass filters available in the CLINIVIEW™ software (Instrumentarium Dental, Tuusula, Finland). Subjective analysis involved evaluating the left, right, and apical surfaces of each implant for the presence of much, few, or no halo. The objective analysis involved measurement of the halo area using the Trainable Weka Segmentation plugin (ImageJ, National Institutes of Health, Bethesda, MD, USA). Data were analyzed using Friedman's test (subjective analysis) and ANOVA (objective analysis) (α = 5%). RESULTS: In the subjective evaluation, the Sharpen 4 filter produced more radiographs with much halo present, and in the objective evaluation, a bigger halo area when compared to the original images and the Noise Reduction filter for all surfaces (p < 0.05). CONCLUSIONS: When evaluating dental implants, priority should be given to original images and those enhanced with smoothing filters since they exhibit fewer halo artifacts. CLINICAL RELEVANCE: Post-processing tools, such as enhancement filters, may improve the image quality and assist some diagnostic tasks. However, little is known regarding the impact of enhancement filters in halo formation on CMOS systems, which have been increasingly used in dental offices.


Assuntos
Artefatos , Implantes Dentários , Estados Unidos , Humanos , Interface Osso-Implante , Óxidos , Semicondutores
4.
J Med Radiat Sci ; 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37965811

RESUMO

INTRODUCTION: A standardised testing protocol for evaluation of a wide range of dental cone beam computed tomography (CBCT) performance and image quality (IQ) parameters is still limited and commercially available testing tool is unaffordable by some centres. This study aims to assess the performance of a low-cost fabricated phantom for image quality assessment (IQA) of digital CBCT unit. METHODS: A customised polymethyl methacrylate (PMMA) cylindrical phantom was developed for performance evaluation of Planmeca ProMax 3D Mid digital dental CBCT unit. The fabricated phantom consists of four different layers for testing specific IQ parameters such as CT number accuracy and uniformity, noise and CT number linearity. The phantom was scanned using common scanning protocols in clinical routine (90.0 kV, 8.0 mA and 13.6 s). In region-of-interest (ROI) analysis, the mean CT numbers (in Hounsfield unit, HU) and noise for water and air were determined and compared with the reference values (0 HU for water and -1000 HU for air). For linearity test, the correlation between the measured HU of different inserts with their density was studied. RESULTS: The average CT number were -994.1 HU and -2.4 HU, for air and water, respectively and the differences were within the recommended acceptable limit. The linearity test showed a strong positive correlation (R2 = 0.9693) between the measured HU and their densities. CONCLUSION: The fabricated IQ phantom serves as a simple and affordable testing tool for digital dental CBCT imaging.

5.
Odontology ; 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37755553

RESUMO

Radiopacities of dental materials used in restorations are very important in making the radiographic diagnosis. Therefore, the aim of our study was to evaluate the radiopacity of five single-shade and six simplishade resin composites with digital technique. Five different single-shade (Charisma Topaz One, Omnichroma, Clearfil Majesty ES-2 Universal, Vittra APS Unique, ZenChroma) and six different simplishade resin composites (G-aenial A'CHORD, Essentia Universal, OptiShade, Estelite Asteria, Filtek Universal, Filtek Z250) were used. For each group, five disk-shaped resin composites of 1 mm and 2 mm thicknesses were prepared. As a control, tooth slices with 1 mm and 2 mm thicknesses and a 99.5% pure aluminum step-wedge were used. The samples, tooth slices, and a step-wedge were placed on a photostimulable phosphor plate. Digital radiographs were taken from 30 and 40 cm distances (70 kVp, 7 mA 0.28 ms). The images were analyzed using ImageJ software to measure the mean gray values. Data were analyzed using SPSS 22 package program and Kruskal-Wallis H Test (p < 0.05). The highest radiopacity was seen in Filtek Universal at both distances and thicknesses. Omnichroma had the lowest radiopacity in all parameters. All specimens showed higher radiopacity than dentin. Except for Omnichroma 1 and 2 mm thick, Clearfil Majesty ES-2 Universal 2 mm thick, samples showed higher radiopacities than enamel (p < 0.05). The restorative materials tested were found to be more radiopaque than dentin. The samples passed the International Organization for Standardization for radiopacity values. The radiopacity values were affected by thickness and type of materials.

6.
J Dent (Shiraz) ; 24(3): 335-341, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37727355

RESUMO

Statement of the Problem: Different software capabilities have been used in digital systems to increase the diagnostic quality of radiographic projections. Considering the availability of different enhancement techniques, it is necessary to determine the suitability of each technique for various diagnostic cases. There is controversy between studies over the effect of different digital enhancement techniques on the accuracy of file length measurements in endodontics. Purpose: The present in vitro study aimed to determine the effect of the software capabilities on the diagnostic accuracy to determine endodontic file lengths in photostimulable phosphor (PSP) radiographs. Materials and Method: In the present in vitro study, standard access cavities were prepared in 44 extracted human single-rooted permanent teeth. An endodontic file was placed in each root canal. PSP sensors were used for digital imaging using the parallel technique. All the images were reviewed on a same monitor; once normally with no software enhancement and once using software manipulations including pseudo-color, sharpness, emboss, and edge enhancement. The distance from the file tip to the rubber stop was measured on the images by an electronic ruler. Results: Significantly, all of the image enhancement techniques presented shorter measurements comparing to the actual length. The results revealed the significant accuracy of the measured error in the pseudo-color enhancement technique compared to other techniques. Conclusion: The results revealed significant differences between the initial measurements (the gold standard) and those made on the manipulated radiographs. In all cases, the measurements were significantly lower than the real values. Therefore, none of these digital enhancement techniques can increase the accuracy of file length measurements significantly. However, manipulation with the pseudo-color option resulted in fewer errors compared to other options and the normal images. Hence, for precise measurements of the endodontic file lengths, pseudo-color processing algorithm can be suggested when using PSP sensors.

7.
Braz. dent. j ; 34(4): 150-157, July-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520332

RESUMO

Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.

8.
Int. j. morphol ; 41(4): 1101-1106, ago. 2023. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1514325

RESUMO

La investigación tuvo como objetivo determinar la influencia de la morfología externa de la raíz de primeros premolares superiores en la existencia de sobreestimación radiográfica durante la preparación para poste. Con este fin se realizó un estudio transversal in vitro, donde 60 premolares superiores uniradiculares fueron instrumentadas con fresas Gates Glidden y Pesso de calibre 1, 2 y 3. Seguidamente se obtuvieron imágenes radiográficas digitales de cada pieza dentaria mediante un aparato posicionador a una distancia constante en sentido vestíbulo lingual, asimismo se realizaron imágenes tomográficas volumétricas de las muestras. En ambas técnicas imagenológicas se midió el espesor a mesial y distal de las piezas. La sobreestimación fue calculada mediante la diferencia de la medida tomográfica menos la radiográfica. Los resultados indicaron que en ambas paredes radiculares hubo diferencia significativa entre las medidas radiográficas y tomográficas (p<0,05), encontrándose en la pared distal diferencias altamente significativas (p<0,001); además se evidenció que la sobreestimación radiográfica fue mayor en la pared distal. El estudio concluyó que existe sobreestimación radiográfica en premolares superiores durante la preparación para poste de un 20,42 % en promedio, siendo la pared distal la estructura que presenta mayor sobreestimación.


SUMMARY: he investigation´s objective was to determine the influence of external morphology of the root of upper first premolars in the existence of radiographic overestimation during preparation for post. An in vitro cross-sectional study was carried out, where 60 single-rooted upper premolars were instrumented with burs. Gates Glidden and Pesso of caliber 1, 2 and 3, then, digital radiographic images of each dental piece were obtained by means of a positioning device at a constant distance in the buccolingual direction; volumetric tomographic images of the samples were also performed. In both imaging techniques, the mesial and distal thickness of the pieces was measured. The overestimation was calculated by the difference of the tomographic measurement minus the radiographic one. The results indicated that in both root walls there was a significant difference between the radiographic and tomographic measurements (p<0.05), with highly significant differences being found in the distal wall (p<0.001); In addition, it was evidenced that the radiographic overestimation was greater in the distal wall. The study concluded that there is radiographic overestimation in upper premolars during post preparation of 20.42% on average, with the distal wall being the structure that presents the greatest overestimation.


Assuntos
Humanos , Dente Pré-Molar/diagnóstico por imagem , Preparo do Dente , Cavidade Pulpar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Dente Pré-Molar/anatomia & histologia , Intensificação de Imagem Radiográfica , Estudos Transversais , Técnica para Retentor Intrarradicular , Preparo de Canal Radicular , Cavidade Pulpar/anatomia & histologia
9.
J Periodontol ; 94(11): 1315-1323, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37332251

RESUMO

BACKGROUND: This study aimed to evaluate the reliability and reproducibility of different non-invasive methods for the assessment of peri-implant mucosal thickness. METHODS: Subjects with two adjacent dental implants in the central maxillary region were included in this study. Three different methods to assess facial mucosal thickness (FMT) were compared: digital file superimposition using Digital Imaging and Communication in Medicine (DICOM) and stereolithography (STL) files of the arch of interest (DICOM-STL), DICOM files alone, and non-ionizing ultrasound (US). Inter-rater reliability agreements between different assessment methods were analyzed using inter-class correlation coefficients (ICCs). RESULTS: A total of 50 subjects with 100 bone-level implants constituted the study population. Assessment of FMT using STL and DICOM files demonstrated excellent inter-rater reliability agreement. Mean ICC values of 0.97 and 0.95 were observed in the DICOM-STL and DICOM groups, respectively. Comparison between the DICOM-STL and US revealed good agreement, with an ICC of 0.82 (95% CI: 0.74 to 0.88) and a mean difference of -0.13 ± 0.50 mm (-1.13 to 0.86). Comparison between DICOM files alone versus US showed good agreement, with an ICC of 0.81 (95% CI: 0.73 to 0.89) and a mean difference of -0.23 ± 0.46 mm (-1.12 to 0.67). Comparison between DICOM-STL and DICOM files revealed excellent agreement, with an ICC of 0.94 (95% CI: 0.91 to 0.96) and a mean difference of 0.1 ± 0.29 mm (LOA -0.47 to 0.46). CONCLUSIONS: Quantification of peri-implant mucosal thickness via analysis of DICOM-STL files, DICOM files, or US assessment are comparably reliable and reproducible methods.


Assuntos
Implantes Dentários , Maxila , Humanos , Estudos Transversais , Reprodutibilidade dos Testes , Maxila/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico
10.
BMC Oral Health ; 23(1): 208, 2023 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-37031221

RESUMO

BACKGROUND: In this study, we investigated whether deep learning-based prediction of osseointegration of dental implants using plain radiography is possible. METHODS: Panoramic and periapical radiographs of 580 patients (1,206 dental implants) were used to train and test a deep learning model. Group 1 (338 patients, 591 dental implants) included implants that were radiographed immediately after implant placement, that is, when osseointegration had not yet occurred. Group 2 (242 patients, 615 dental implants) included implants radiographed after confirming successful osseointegration. A dataset was extracted using random sampling and was composed of training, validation, and test sets. For osseointegration prediction, we employed seven different deep learning models. Each deep-learning model was built by performing the experiment 10 times. For each experiment, the dataset was randomly separated in a 60:20:20 ratio. For model evaluation, the specificity, sensitivity, accuracy, and AUROC (Area under the receiver operating characteristic curve) of the models was calculated. RESULTS: The mean specificity, sensitivity, and accuracy of the deep learning models were 0.780-0.857, 0.811-0.833, and 0.799-0.836, respectively. Furthermore, the mean AUROC values ranged from to 0.890-0.922. The best model yields an accuracy of 0.896, and the worst model yields an accuracy of 0.702. CONCLUSION: This study found that osseointegration of dental implants can be predicted to some extent through deep learning using plain radiography. This is expected to complement the evaluation methods of dental implant osseointegration that are currently widely used.


Assuntos
Aprendizado Profundo , Implantação Dentária Endóssea , Implantes Dentários , Osseointegração , Humanos , Implantação Dentária Endóssea/métodos , Radiografia/métodos
11.
Radiography (Lond) ; 29(3): 533-538, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36913788

RESUMO

INTRODUCTION: The daily image quality assessment involves large datasets that consume a lot of time and effort. This study aims to evaluate a proposed automated calculator for image distortion analysis in 2-dimensional (2D) panoramic imaging mode for a dental cone beam computed tomography (CBCT) system in comparison with present manual calculations. METHODS: A ball phantom was scanned using panoramic mode of the Planmeca ProMax 3D Mid CBCT unit (Planmeca, Helsinki, Finland) with standard exposure settings used in clinical practice (60 kV, 2 mA, and maximum FOV). An automated calculator algorithm was developed in MATLAB platform. Two parameters associated with panoramic image distortion such as balls diameter and distance between middle and tenth balls were measured. These automated measurements were compared with manual measurement using the Planmeca Romexis and ImageJ software. RESULTS: The findings showed smaller deviation in distance difference measurements by proposed automated calculator (ranged 3.83 mm) as compared to manual measurements (ranged 5.00 for Romexis and 5.12 mm for ImageJ software). There was a significant difference (p < 0.05) on the mean measured ball diameter between automated and manual measurement. For ball diameter measurement, there is a moderate positive correlation between automated measurement with the manual measurements (r = 0.6024 and r = 0.6358 for Romexis and ImageJ, respectively). However, there is a negative correlation between automated measurement for the distance difference with manual methods (r = -0.3484 and r = -0.3494 for Romexis and ImageJ, respectively). There was a good approximation between automated and ImageJ measurement of ball diameter in comparison to reference value. CONCLUSION: In conclusion, the proposed automated calculator provides faster method with an accurate and acceptable results for daily-basis image quality test in dental panoramic mode of a Dental CBCT imaging system in comparison to current manual method. IMPLICATIONS FOR PRACTICE: An automated calculator is recommended for image distortion analysis on phantom images in routine image quality assessment for dental panoramic mode of Dental CBCT imaging system that may involve analysis of large image datasets. It offers improvement in routine image quality practice in term of time and accuracy.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Radiografia Panorâmica , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos
12.
J Periodontol ; 94(8): 944-955, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36797817

RESUMO

BACKGROUND: The purpose of this study was to determine the association between periodontal supracrestal soft tissue dimensions (PSSTDs) and other phenotypic features in non-molar maxillary teeth. MATERIALS AND METHODS: Adult subjects in need of comprehensive dental treatment were recruited. Periodontal phenotypic variables (i.e., facial and palatal gingival thickness [GT], alveolar bone thickness [BT], and PSSTDs, namely distance from the gingival margin to the bone crest defined as periodontal supracrestal tissue height [PSTH] and distance from the cementoenamel junction to the bone crest [CEJ-BC]) were recorded using cone-beam computed tomography scans. Standardized intraoral photographs were obtained to assess facial keratinized tissue width (KTW) and other anatomical parameters (i.e., tooth type, gingival architecture, and interproximal papilla height). RESULTS: The study sample was constituted of 87 participants that contributed with a total of 522 maxillary anterior teeth. Differences in mean values of PSSTDs, KTW, GT, and BT were observed between tooth types and sex. Males exhibited a thicker GT and BT, and taller PSTH and KTW compared to females. Shorter CEJ-BC was associated with shorter PSTH, wider KTW, and thicker GT and BT. Shorter PSTH was associated with thicker facial BT. Notably, BT and GT were positively correlated at both facial and palatal sites, meaning that the thicker the gingival phenotype, the thicker the bone morphotype. Facial BT and facial GT were positively correlated with KTW. A flat gingival architecture was associated with the thick periodontal phenotype. Square teeth had shorter CEJ-BC, wider KTW, and thicker GT. CONCLUSIONS: Periodontal phenotypic features vary across and within subjects, between facial and palatal sites at different apico-coronal levels, and as a function of sex and tooth type. The shorter the PSSTDs, the wider the KTW and the thicker the GT and BT. PSSTDs, particularly PSTH, should be considered an integral component of the periodontal phenotype.


Assuntos
Gengiva , Maxila , Masculino , Feminino , Animais , Estudos Transversais , Maxila/diagnóstico por imagem , Gengiva/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Fenótipo
13.
Braz. dent. j ; 34(1): 39-44, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420574

RESUMO

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

14.
Oral Radiol ; 39(2): 418-424, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36076131

RESUMO

OBJECTIVES: This study aims to evaluate the effects of histogram equalization (HE) and contrast limited adaptive histogram equalization (CLAHE) on periapical images and fractal dimensions in the periapical region. METHODS: In this cross-sectional study, digital periapical images were selected from the archive of Dentistry School of Isfahan University of Medical Sciences. The radiographs were taken from mandibular and maxillary anterior single root teeth with healthy root and periodontium. After applying HE and CLAHE algorithms to images, two radiologists evaluated the quality of apex detection from using a 5-point Likert scale (from 5 for very good image quality to 1 for very bad image quality). Afterward, all the images were imported to the ImageJ application, and the region of interest (ROI) was specified as the region between the two central incisors. The fractal box-counting method was used to determine fractal dimensions (FD) values. Nonparametric Wilcoxon-Friedman test, Intraclass Correlation Coefficient test, T-test, and Pair T-test were performed as statistical analysis (α = 0.05). RESULTS: Fifty-three radiographs were analyzed and the image quality assessments were significantly different between raw images and images after performing HE, CLAHE (p value < 0.001), and using CLAHE algorithm significantly increases image quality assessments more than HE (p value = 0.009). There was a significant difference in FD values for images after applying CLAHE and HE compared to raw images (p value < 0.001), and HE decreased the FD value significantly more than CLAHE (p value = 0.019). CONCLUSIONS: Employing CLAHE and HE algorithm via OpenCV python library improves the periapical image quality, which is more significant using the CLAHE algorithm. Moreover, applying CLAHE and HE reduces trabecular bone structure detection and FD values in periapical images, especially in HE.


Assuntos
Algoritmos , Fractais , Estudos Transversais , Radiografia , Mandíbula
15.
Acta odontol. Colomb. (En linea) ; 13(1): 26-39, 20230000. ilus, ilus, tab, tab
Artigo em Espanhol | LILACS | ID: biblio-1425208

RESUMO

Objetivo: establecer la relación entre el diagnóstico histopatológico de sacos foliculares de terceros molares y la medida radiográfca estandarizada en radiografía panorámica digital. Métodos: se llevó a cabo un estudio descriptivo en el que se incluyeron 28 sacos foliculares de terceros molares. Dos observadores midieron la radiolucidez pericoronal en radiografías panorámicas digitales usando un método estandarizado y se calculó el índice de correlación intraclase. Se estableció un diagnóstico radiográfco según la medida del saco, con <2.5 mm como el límite para sacos foliculares normales. Dicho diagnóstico fue comparado con el respectivo diagnóstico histopatológico. Se calculó sensibilidad y especifcidad; se aplicó la prueba de chi-cuadrado, exacta de Fisher y, fnalmente, el índice Kappa. Resultados: se obtuvo un alto grado de acuerdo entre los observadores. La prueba radiográfca tuvo una baja sensibilidad (0.27) y especifcidad (0.6) y no se encontró diferencia estadísticamente signifcativa entre estos. Conclusiones: la ausencia de hallazgos radiográfcos no implica ausencia de enfermedad. Además, no se puede establecer relación entre la presencia de quistes dentígeros y radiolucidez ≥ 2.5 mm en radiografía panorámica digital.


Objective: To establish the relationship between the histopathological diagnosis of follicular sacs of third molars and the standardized radiographic measurement in digital panoramic radiography. Methods: This was a descriptive study in which 28 follicular sacs of third molars were included. In digital panoramic radiographs two observers measured the pericoronal radiolucency using a standardized method and the intraclass correlation index was calculated. A radiographic diagnosis was established according to the size of the sac, with <2.5mm being the limit for normal follicular sacs. This diagnosis was compared with the respective histopathological diagnosis. Sensitivity and specifcity were calculated; the chi-square test, Fisher's exact test and fnally the Kappa index were applied. Results: A high degree of agreement was obtained among the observers. The radiographic test had a low sensitivity (0.27) and specifcity (0.6) and no statistically signifcant diference was found between these. Conclusions: The absence of radiographic fndings does not imply absence of disease, furthermore, no relationship can be established between the presence of dentigerous cysts and radiolucency ≥ 2.5 mm in digital panoramic radiography.


Assuntos
Humanos , Adulto , Cisto Dentígero , Dente Serotino , Patologia , Radiografia Panorâmica , Cistos
16.
Odovtos (En línea) ; 24(3)dic. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1406166

RESUMO

Abstract The aim of this study was to assess the use of digital dental radiology in Brazil, by focusing on the use of image receptors, imaging exams and digital image enhancement tools, also assessing the methods of professional image transfer. Questionnaires were distributed in person on dental meetings and digitally via messaging (WhatsApp®) and mailings list. The sample of this cross-sectional study consisted of 478 questionnaires. Most participants were woman (n=315, 65.9%), with average age of 33.8±9.2 years. Descriptive and frequency analysis was performed. Chi-square and Fisher's exact tests were used (α=0.05). Most dentists worked at shared dental clinics (34.7%) and use digital image receptors (51.1%), but a representative percentage (48.9%) still exclusively use radiographic films. Photostimulable phosphor plate is the most used digital image receptor. Among extraoral exams, panoramic radiography (PAN) is the most used. Regarding dental specialties, oral radiologists and oral and maxillofacial surgeons mostly use cone-beam computed tomography (p<0.001). Most dentists who use digital systems make use of digital image enhancement tools (87.8%), mainly contrast, zoom, brightness and measurements. The most common method of professional image transfer (professional-professional and professional-patiens) is by email, with few dentists using online app and social media (26%). Therefore, while most Brazilian dentists use digital imaging systems, a significant percentage still exclusively use radiographic films. The most extraoral imaging exams used is PAN. Regarding image enhancement tools, brightness and contrast adjustments, zoom and measurements are the most applied. Finally, dentists generally use email for professional image transfer.


Resumen El objetivo de este estudio fue evaluar uso de la radiología dental digital en Brasil, centrándose en uso de receptores de imagen, exámenes de imágenes y herramientas de mejora de imagen digital, evaluando también los métodos de transferencia de imagen profesional. Cuestionarios se distribuyeron de forma presencial en reuniones odontológicas y de forma digital a través de mensajería (WhatsApp®) y lista de correo. Muestra de este estudio transversal estuvo compuesta por 478 cuestionarios. Mayoría de los participantes eran mujeres (n=315, 65,9%), con edad promedio de 33,8±9,2 años. Se realizó un análisis descriptivo y de frecuencias. Se utilizaron las pruebas Chi-cuadrado y exacta de Fisher (α=0,05). La mayoría de los odontólogos trabajaban en clínicas dentales compartidas (34,7%) y utilizan receptores de imágenes digitales (51,1%), pero un porcentaje representativo (48,9%) todavía utiliza exclusivamente películas radiográficas. Placa de fósforo fotoestimulable es el receptor de imagen digital más utilizado. Entre los exámenes extraorales, la radiografía panorámica (PAN) es la más utilizada. En cuanto a las especialidades odontológicas, los radiólogos orales y los cirujanos orales y maxilofaciales utilizan mayoritariamente la tomografía computarizada de haz cónico (p<0,001). Mayoría de los odontólogos que utilizan sistemas digitales utilizan herramientas de mejora de imagen digital (87,8%), principalmente contraste, zoom, brillo y medidas. Método más común de transferencia de imágenes profesionales (profesional-profesional y profesional-pacientes) es por correo electrónico, con pocos dentistas que utilizan aplicaciones en línea y redes sociales (26%). Por lo tanto, mientras que la mayoría de dentistas brasileños utilizan sistemas de imágenes digitales, un porcentaje significativo aún utiliza exclusivamente películas radiográficas. Examen de imagen extraoral más utilizado es el PAN. En cuanto a las herramientas de mejora de imagen, los ajustes de brillo y contraste, el zoom y las medidas son las más aplicadas. Finalmente, los dentistas generalmente usan el correo electrónico para la transferencia de imágenes profesionales.


Assuntos
Intensificação de Imagem Radiográfica/tendências , Sistemas de Informação em Radiologia , Brasil , Diagnóstico por Imagem
17.
Clin Oral Investig ; 26(7): 4743-4752, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35267096

RESUMO

OBJECTIVES: To evaluate the influence of digital filters of intraoral radiographic systems on the diagnosis of simulated internal and external root resorptions and image quality. MATERIALS AND METHODS: Internal root resorption (IRR) and external root resorption (ERR) were simulated in 34 teeth. For image acquisition, two radiographic systems were used: Digora Toto and VistaScan. All filters available in these systems were applied. Three observers scored the detection of root resorptions in a 5-point scale. The noise and the contrast-to-noise ratio (CNR) were calculated. The area under ROC curve, sensitivity, specificity, and accuracy were obtained. One-way ANOVA with Tukey's post hoc tests compared the diagnostic values, noise, and CNR between the filters (α = 0.05). RESULTS: For ERR, there were no significant differences in diagnostic values between the filters tested for both systems. For IRR, Original and Noise Reduction filters presented higher sensitivity than the Sharpen2 filter for images from Digora Toto, with no differences between the other groups. For VistaScan, there were no significant differences of diagnostic values between the groups studied. Noise values differed among the filters of both systems. The CNR of the filters differed only for the bone region for Digora Toto, while for VistaScan, both tooth and bone regions differed. CONCLUSIONS: Despite promoting changes in pixel intensities and affecting the noise level of the radiographic images, the digital filters of Digora Toto and VistaScan systems do not affect the diagnosis of internal or external root resorptions. CLINICAL RELEVANCE: Digital filters are common tools in digital radiographic systems and may be used by the professional without impairment in root resorptions diagnosis.


Assuntos
Reabsorção da Raiz , Humanos , Curva ROC , Radiografia Dentária Digital/métodos , Reabsorção da Raiz/diagnóstico por imagem , Raiz Dentária
18.
Dentomaxillofac Radiol ; 51(5): 20210483, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35348365

RESUMO

OBJECTIVES: This study aims to investigate if automated analyses of the trabecular pattern in intraoral radiographs independently contribute to fracture risk assessment when other risk factors incorporated in the Fracture Risk Assessment Tool (FRAX) are taken into account. A secondary aim is to explore the correlation between the automated trabecular pattern assessment in intraoral radiographs and Trabecular Bone Score (TBS). METHODS: A total of 567 intraoral radiographs from older females participating in a large population-based study (SUPERB) based in Gothenburg, Sweden, were selected to analyse trabecular pattern using semi-automated and fully automated software. Associations between trabecular pattern analysis and incident fractures were studied using Cox proportional hazard model, unadjusted and adjusted for FRAX risk factors (previous fracture, family history of hip fracture, smoking, corticosteroids, rheumatoid arthritis, without and with bone mineral density (BMD) of the femoral neck). In addition, the correlation between trabecular pattern analysis and TBS of the lumbar spine was investigated using Pearson correlation analysis. RESULTS: Neither the unadjusted nor the adjusted trabecular pattern analysis in intraoral radiographs was significantly associated with any fracture or major osteoporotic fracture (MOF). A weak correlation was found between semi-automated trabecular pattern analysis and TBS. No correlation was found between the fully automated trabecular pattern analysis and TBS. CONCLUSIONS: The present study shows that semi-automated and fully automated digital analyses of the trabecular pattern in intraoral radiographs do not contribute to fracture risk prediction. Furthermore, the study shows a weak correlation between semi-automated trabecular pattern analysis and TBS.


Assuntos
Fraturas por Osteoporose , Absorciometria de Fóton , Densidade Óssea , Osso Esponjoso/diagnóstico por imagem , Feminino , Colo do Fêmur/diagnóstico por imagem , Humanos , Vértebras Lombares , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/etiologia , Medição de Risco , Fatores de Risco
19.
J Periodontol ; 93(6): 847-856, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35289400

RESUMO

BACKGROUND: There is limited information on the need for bone augmentation in the context of delayed implant placement whether alveolar ridge preservation (ARP) is previously performed or not. The primary aim of this retrospective cohort study was to evaluate the efficacy of ARP therapy after tooth extraction compared with unassisted socket healing (USH) in reducing the need for ancillary bone augmentation before or at the time of implant placement. METHODS: Adult subjects that underwent non-molar single tooth extraction with or without simultaneous ARP therapy were included in this study. Cone beam computed tomography scans obtained before tooth extraction and after a variable healing period were used to record the baseline facial bone thickness and to virtually plan implant placement according to a standard method. A logistic regression model was used to evaluate the effect of facial alveolar bone thickness upon tooth extraction and baseline therapy (USH or ARP) on the need for additional bone augmentation, adjusting for several covariates (i.e., age, sex, baseline KMW, and tooth type). RESULTS: One hundred and forty subjects that were equally distributed between both baseline therapy groups constituted the study population. Implant placement was deemed virtually feasible in all study sites. Simultaneous bone augmentation was considered necessary in 60% and 11.4% of the sites in the USH and ARP group, respectively. Most of these sites (64.2% in the USH group and 87.5% in the ARP group) exhibited a thin facial bone phenotype (<1 mm) at baseline. Logistic regression revealed that the odds of not needing ancillary bone augmentation were 17.8 times higher in sites that received ARP therapy. Furthermore, the need for additional bone augmentation was reduced 7.7 times for every 1 mm increase in facial bone thickness, regardless of baseline therapy. CONCLUSIONS: Based on a digital analysis, ARP therapy, compared with USH, and thick facial alveolar bone largely reduce the need for ancillary bone augmentation at the time of implant placement in non-molar sites.


Assuntos
Perda do Osso Alveolar , Aumento do Rebordo Alveolar , Adulto , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/prevenção & controle , Perda do Osso Alveolar/cirurgia , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/cirurgia , Aumento do Rebordo Alveolar/métodos , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Masculino , Estudos Retrospectivos , Extração Dentária , Alvéolo Dental/diagnóstico por imagem , Alvéolo Dental/cirurgia
20.
Dentomaxillofac Radiol ; 51(4): 20210404, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34860568

RESUMO

OBJECTIVES: To assess the dynamic range and enhancement ability of radiographs acquired with contemporary digital systems. METHODS: Five repeated periapical radiographs of human mandibles with an aluminium step-wedge were acquired using two sensor-based and three photostimulable phosphor plate-based systems and an X-ray unit at ten exposure times 0.020, 0.032, 0.063, 0.080, 0.100, 0.200, 0.320, 0.400, 0.500, and 0.630 s. All images had their brightness and contrast enhanced by two experienced oral and maxillofacial radiologists in consensus and were exported as both the original and enhanced file formats. Mean grey values were obtained from the aluminium steps and tabulated with their corresponding thicknesses for each exposure time, digital radiographic system, and file format. Images with saturated steps were excluded and the mean grey values from the remaining images were averaged to assess image brightness and the angular coefficient of the linear trendlines was generated from the relationship between mean grey values and their corresponding aluminium thicknesses to assess image contrast. Brightness and contrast values were compared using two-way ANOVA with post-hoc Tukey (α = 0.05). RESULTS: Photostimulable phosphor plate-based digital radiographic systems had a broader dynamic range. Longer exposure times produced original images with lower brightness and variable contrast (p < 0.05). Subjective enhancement significantly increased or reduced brightness and/or contrast in some systems (p < 0.05). CONCLUSIONS: Contemporary digital radiographic systems present different dynamic ranges and exposure-related brightness and contrast. Image enhancement may be a valuable tool at slightly suboptimal exposure times.


Assuntos
Alumínio , Radiografia Dentária Digital , Humanos , Mandíbula , Intensificação de Imagem Radiográfica/métodos , Radiografia Dentária Digital/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...